High-efficiency steam traps & condensate recovery systems

Natural Gas Special Trap 50

Category:Special steam trap for natural gas

Overview


Natural gas trap valve

TSS43H series natural gas trap valve is a fully automatic liquid discharge device, the product that sedimentary water gas water separator or gas tank gas in power without the use of other conditions (liquid) to achieve automatic discharge, waste water (liquid) without gas leakage in the process of avoiding artificial schedule (liquid) caused by natural gas losses (about 1% of production), to ensure supply of quality, purifying the environment, the implementation of cleaner production, eliminate safety hazards and improving working conditions have a remarkable effect.


:

1、 100%。

functional features:

1、all-weather automatic continuous operation, there is water on the row, no water automatic shutdown, sink water (liquid) discharge rate of 100%.

2、gas tight, no gas leakage in operation, the leakage rate is zero.

3、automatic settlement of dirt, the implementation of regular sewage.

4、the internal material for all stainless steel, inside the valve to avoid corrosion treatment, long service life.

5、easy installation, no debugging, smooth operation, safe and reliable.



Technical characteristics:

Model

Nominal

 diameter

(mm)

Nominal

Pressure

(MPa)

Working

Pressure

(MPa)

working

Temperature

(℃)

Displacement

(M3/h)

Leak

rate

(%)

Drainage

 rate

(%)

TSS43H-16

25

32

40

50

65

80

100

150

1.6

≤1.6

Ambient temperature

2-50

0

100

TSS43H-25

2.5

≤2.0

TSS43H-40

4.0

≤3.0

TSS43H-63

6.3

≤5.0

TSS43H-100

10.0

≤8.0





: a、

Outline drawing:   a、Intake         b、Air return port       c、Inspection Gate         d、Outfall            e、sewage outfalls            f、Reserve portM20×1.5Plug


:


model, specification, work parameter year, installation size:

TSS43H natural trap according to the liquid can be divided into different components of A series and B series of two.

The A series means that the liquid is water free and has no other liquid components (Table 1).

The B series represents a mixture of liquids that can be dispersed as oil or water and condensate (table two).

If natural gas contains H2S gas, sulfur resistant natural gas traps shall be selected. The type of sulfur resistant natural gas trap is common type of natural gas trap, plus "K"". The model in the table is the anti sulfur trap of the corresponding model.


Model

Specif

ication

number

Nominal

pressure

(MPa)

Working

 parameter

Installation

 size

Exit

Comprehen

sive

Descr

iption

Working

ressure

(MPa)

Displacement

(M3/h)

H1

mm

H2

mm

H3

mm

L

mm

Icon

DN

mm

PN

MPa

TSS43H-16

(KTSS43H-16)

A1

1.6

0.8

2

500

200

680

540

 

40

 

 

50

 

65

 

 

 

80

 

 

100

1.6

 

 

DN40,

H4=100mm;

81-94

 

  

 

A2

5

600

200

780

600

A3

10

730

200

910

600

A4

15

850

200

1030

630

A5

1.5

2

500

200

680

540

A6

5

600

200

780

600

A7

10

730

200

910

600

A8

15

730

200

910

630

TSS43H-25

(KTSS43H-25)

 

A9

2.5

2.0

2

500

200

680

540

2.5

A10

5

600

200

780

600

A11

10

860

200

1040

600

A12

15

880

200

1060

630

TSS43H-40

(KTSS43H-40)

A13

4.0

3.0

2

580

200

750

540

4.0

A14

5

600

200

770

600

A15

10

880

320

1180

630

A16

15

1000

320

1320

630

TSS43H-63

(KTSS43H-63)

A17

6.3

4.5

2

710

200

900

540

6.3

A18

5

730

200

920

600

A19

10

1000

320

1320

630

A20

15

1150

320

1470

630

A21

5.5

2

710

200

900

540

A22

5

730

200

920

620

A23

10

1000

320

1320

630

TSS43H-100

(KTSS43H-100)

A24

10.0

6.0

2

710

200

900

540

10.0

A25

5

730

200

920

620

A26

10

1120

340

1140

680

A27

8.0

2

880

340

1180

620

A28

5

1120

340

1420

620

A29

10

1120

340

1440

680

 



                                                                                                                   

Model

Specif

ication

number

Nominal

pressure

(MPa)

Working

parameter

Installation

size

Imported

Exit

Compreh

ensive

description

Working

pressure

(MPa)

Displacement

(M3/h)

H1

mm

H3

mm

L

mm

Icon

DN

mm

PN

MPa

 

TSS43H-16

(KTSS43H-16)

B1

1.6

0.8

2

700

200

880

540

 

 

 

40

 

 

 

50

 

 

 

65

 

80

 

 

100

 

1.6

 

1

DN40,

PN

H4=

100mm; 

2

DN15,

PN

3

PN≤

2.5MPa

JB/T

81-94  

2.5<

PN≤

10Mpa

JB/T

82.2-94A

B2

5

730

200

910

600

B3

10

850

200

1030

630

B4

1.5

2

700

200

880

540

B5

5

850

200

1030

600

B6

10

850

200

1030

600

TSS43H-25

(KTSS43H-25)

B7

2.5

2.0

2

700

200

880

540

2.5

B8

5

730

200

910

600

B9

10

1030

320

1350

630

TSS43H-40

(KTSS43H-40)

B10

4.0

3.0

2

600

200

980

600

4.0

B11

5

850

200

1030

600

B12

10

1030

320

1350

630

TSS43H-63

(KTSS43H-63)

B13

6.3

4.5

2

730

200

910

600

6.3

B14

5

1000

320

1320

630

B15

10

1150

320

1450

630

B16

5.5

2

730

200

910

600

B17

5

1030

320

1350

630

TSS43H-100

(KTSS43H-100)

B18

10.0

6.0

2

850

200

1030

620

10.0

B19

3

980

200

1160

620

B20

8.0

2

1150

340

1470

620

B21

3

1150

340

1470

620












Installation and maintenance:

1, the valve should be installed horizontally in the pipeline, the lower position, the valve should be installed before the cut-off valve, filter bypass valve installed at the same time.

2, the trap installed, open the inlet stop valve, and then open the outlet valve, the trap began to run normally, drainage continuous operation.

3. Installation direction: the arrow on the valve body is in line with the direction of the fluid in the pipe (arrow pointing to the outlet of the fluid).

4, sewage clearance: as a result of long-term accumulation, with the condensate into the trap cavity, there will be a certain amount of slag.

5, sewage operation: close the trap before and after the cut-off valve, and then open the bottom dirty ball valve, and then slowly open the inlet stop valve, with condensed water to wash the valve cavity slag, until the rinse clean inside.

6, in order to prevent slag into the trap, according to the user's respective pipe conditions, regular cleaning debris, can make trap to maintain good normal work.



↑