High-efficiency steam traps & condensate recovery systems

Bellows Seal Trap ZF80S

Category:Bellows Traps

Overview


Bellows seal trap
The thermo-sensitive element of bellows seal traps is bellows filled with volatile liquid,which employs the volatility of the liquid and flexibility of the bellows.When temperature of the steam pipe goes up,the liquid volatilizes into gas,the size expands and produces pressure to impel bellows to stretch.In contrast,when temperature of the steam pipe goes down to the temperature for gas to turn into liquid,the size gets smaller and the bellows contract due to lack of impetus.









Merits
1.Convenient use due to adjustable water discharge temperature ranging from 70 to 100 degrees.
2.Capability to prevent discharge of high-temperature condensate so as to maintain heat energy of the steam pipe.
3.Continuous water discharge without noise.
4.Free from the effect of small fluctuation of steam pressure.
5.Simple structure,small size and easy installation.
6.Improvement of discharge capacity condensate by increasing diameter of bellows.
7.Good air diameter performance with resistance to coldness.
8.Zero leakage and backpressure ratio up to 75%.





Installation/attention for use
Before the installment of pipeline,use the steam to blow off the pollutant.The arrow shows the direction consistent with the flow direction.
Ahead of the trap,the thermal tube of 1~2 meters need no heat-preservation.Be installed at thermal position lower than the condensation water discharge point of the steam-using equipment.
Before leaving the plant,the hydrophobic temperature of trap has been adjust around 95℃.If it is needed to change the hydrophobic temperature or the displacement,open the shielding bonnet,loosen the lock nut,revolve the adjusting screw revolve the valve core clockwise,the hydrophobic volume reduces and the hydrophobic temperature drops;revolve it counterclockwise,the valve core backlashes,the hydrophobic volume increases,and the hydrophobic temperature rises.After the adjustment ended,tighten the lock nut.
It is needed to make the periodic maintenance and clear the pollutant before the filtration screen,so as to guarantee the trap work normally.



Shell

pressure

grade

Maximum

Operating

 pressure

differential

Maximum

 Allowable

 temperature

Permitted

 Backpressure

 rate

1.6、2.5MPA

1.6MPA

350℃

75%

Freezing

 resistance

Air

exhaust

system

Used

medium

Energy

saving

 effect

Load

 leakage

 Excellence

  Automatic

Steam、

condensate

water

 Excellence

0%


Part and component name

Material

 Valve Body、Valve Cover

Carbon steel、Stainless steel

Reservoir

 Stainless steel、Volatile liquid

Valve seat

 High chrome stainless steel、Four Fluorine

Filtrating screen

 Stainless steel


Product

model

Calibre

Flange

Thread/

welding

H1

H2

W

weight

Pressure

Change

 range

(MPa)

Nominal

 pressure

ZF80S-2

CS14F-16

15~25

32-50

-

136

175

37

55

67

100

40

74

1.2

2.3

0.1-1.6

2.5






Note
1.Please provide operating pressure and operating pressure difference,generating quantity of condensate water,operating temperature,connecting mode and standards in selecting product models.
2.The load of condensate Water's safety coefficient reaches 2 to 3 times in general.
3.Please make sure the drain valve is installed properly,maintained regularly,cleaned up and operates under the normal condition,so as to extend its service life.

Key specifications

Valve Body, Valve CoverCarbon steel, Stainless steel
ReservoirStainless steel, Volatile liquid
Valve seatHigh chrome stainless steel, Four Fluorine
Filtrating screenStainless steel
↑